Proline | 28N1 Formenti F19 | Vol cont bar will not move above 3 notches (not in hotel mode) | EEPROM corrupt - enter service mode by pressing "vol up" on TV whilst sw set on & within 3 sec's press "standby" on R/C (still holding "vol up"). Service mode options now on screen. Make a note of settings!! Scroll up to "INIT CTVFOR-P V1.3" press "vol up" (toggle) & wait 2 sec's to finish. | 14-09-04 |